1. Vertical Airflow Direction
Cooling and Soft Dry Mode
•
The louver swings up and down as shown above.
•
The louver does not swing when the Indoor Fan stops
during operation.
during operation.
2. Vertical Airflow Direction
Heating Mode
•
When the intake air temp. reaches 38°C, the louver is
changed from upper to lower limit. When the intake air
temp falls to 35°C, the louver is changed from lower to
upper limit.
changed from upper to lower limit. When the intake air
temp falls to 35°C, the louver is changed from lower to
upper limit.
•
The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.
shown above) when pressing Manual Airflow Direction
Selection Button.
•
The louver can be selected between 0° - 61° (as shown
above)
above)
when
pressing
Manual
airflow
Direction
Selection Button.
8.10. Airflow Direction Control
3. Horizontal Airflow Direction
•
The left and right airflow direction louvers can be adjusted manually.
30
S-A75KE CU-A75KE / CS-A95KE CU-A95KE / CS-A125KE CU-A125KE