8.11. Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
However consumer is advised to use Economy Mode operation after the room temperature reaches the desired temperature.
 1. Cooling and Soft Dry Mode
  • 
When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the present setting
temperature. This operation automatically will be running under Random Fan speed.
  • 
Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
 2. Heating Mode
  • 
When the Economy Mode is set, the temperature will be automatically decreased 0.5°C against the present setting
temperature.
  • 
The Fan Speed will shift as shown below:
  • 
Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
 3. Economy Mode will stop if:
  • 
Economy mode button is pressed again.
  • 
Stopped by ON / OFF switch.
  • 
Timer-off activates.
  • 
Powerful mode button is pressed.
  • 
Fan Speed control button is pressed.
  • 
Sleep mode button is pressed ON.
  • 
Operating mode is changed.