18
7-3. HOW TO C HE C K T HE WAT E R LE VE L F R E QUE NC Y
7-4. HOW TO K NOW TO T E MP E R AT UR E OF E AC H T HE R MIS TOR
AT OP E R AT ING C ONDIT ION.
T he digits means water level frequency. (10
-1
kHz)
ex) 241 : Water level frequency = 241 x 10
-1
kHz
24.1 kHz
P ress the
P re wash
and
S pin
button simultaneously
.
P ress the
Medic R inse
and
S pin
button simultaneously .
T hermistor in tub temperature.