32LG3DCH (CHASSIS:LA76B) - LG TV Service Manual (repair manual). Page 12

Read LG 32LG3DCH (CHASSIS:LA76B) Service Manual online

- 12 -
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
5.3. HDCP setting
(High-Bandwidth Digital Contents Protection)
1) Connect D-sub Signal Cable to D-Sub Jack.
2) Input HDCP key with HDCP-key- in-program.
3) HDCP Key value is stored on EEPROM(AT24C512) which
is 80~A1 addresses of  0xA0~0xA2 page
4) Write data by 64bytes.
5) AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
6) HDCP Key value is different among the sets. 
5.4. Outgoing condition Configuration 
1) After all function test., press IN-STOP Key by SVC Remote
controller. And Make Ship Condition. 
2) When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then turn off automatically.
(Must not AC power OFF during blinking)
1) Test Voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
2) Test Point
- GND Test = between power cord GND and Signal cable
metal GND
AC input Live.
3) leakage current: 0.5mArms (but, 32LG3DCH as hospital TV
limited by 0.1mArms.)
Page of 34
Display