–18–
Earth cable
Cover control
Main terminal board
Control terminal board
Outdoor
Indoor
Control terminal board
Control box
Control box cover
(On which the Electric
Wiring Connection is put)
A
A view
Remote
control cord
control cord
Connection
cord between
the indoor unit
and the
outdoor unit
cord between
the indoor unit
and the
outdoor unit
Cord clamper
1
1
Main
power source
Switch box
Circuit Breaker
Use a 25A(24K)
circuit breaker or time
delay fuse.
circuit breaker or time
delay fuse.
ELECTRICAL WIRING
INDOOR UNIT
• Remove the control box cover for electrical con-
nection between the indoor and outdoor
unit.(Remove two screws
unit.(Remove two screws
➀
.)
• Use the cord clamper to fix the cord.
Perform the electrical wiring work according to the electrical wiring
connection.
connection.
• All wiring must comply with local requirements.
• Select a power source that is capable of supply-
• Select a power source that is capable of supply-
ing the current required by the air conditioner.
• Use a recognized circuit breaker 25A(24K)
between the power source and the unit. A discon-
nection device to adequately disconnect all supply
lines must be fitted.
nection device to adequately disconnect all supply
lines must be fitted.
WIRING CONNECTION
OUTDOOR UNIT
• Remove the control cover for wiring connection.
• Use the cord clamper to fix the cord.
• Earthing work
Connect the cable of diameter 1.6mm
2
or more to
the earthing terminal provided in the control box
and do earthing.
and do earthing.
¡
Please check !!