LB-D2460HL - LG Air Conditioner Service Manual (repair manual). Page 15

Read LG LB-D2460HL Service Manual online

3. The Indoor Unit Installation
• Select and mark the position for fixing bolts.
• Drill the hole for set anchor on the face of ceiling.
• Insert the set anchor and washer onto the sus-
pension bolts for locking the suspension bolts on
the ceiling.
• Mount the suspension bolts to the set anchor
firmly.
• Secure the installation plates onto the suspen-
sion bolts (adjust level roughly) using nuts, wash-
ers and spring washers.
–15–
Tighten the nut and bolt to prevent unit falling
CAUTION
• Local supply
¤
Set anchor
¤Ł
Plate washer 
- M10
¤Ø
Spring washer
- M10
¤Œ
Nut 
- W3/8 or M10
¤º
Suspension bolt
- W3/8 or M10
1 Set anchor
Old building
New building
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
   bolts
Page of 40
Display

Click on the first or last page to see other LB-D2460HL service manuals if exist.