GTO 14001 (serv.man3) - JBL Car Audio EMC - CB Certificate (repair manual). Page 7

Read JBL GTO 14001 (serv.man3) EMC - CB Certificate online

 
EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
____________________________________________________________________________________________________________ 
Holytech (HK) Certification Co., Limited  
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai  
Tel : 00852-36458129    FAX : 00852-36458092   
Report No.:
 
HL-S07062713
 
                 
  Page 7 of 28 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No changing voltage setting 
device 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials 
used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by 
hand. 
8.5 
Class I equipment 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
Basic insulation complies 
with requirements specified 
in clause 10 and 13. 
 
Resistors bridging basic insulation complying with 
14.1 a) 
No resistors bridging basic 
insulation. 
8.6 
Class II equipment and Class II constructions within 
Class I equipment 
Class I appliance 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
Double/Reinforced 
insulation complies with 
requirements specified in 
clause 10 and 13. 
N  
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
The apparatus have 
isolating transformers 
complies with clause 14.3 
N  
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) 
No such capacitor. 
 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
No such capacitor. 
 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
Certified capacitor is 
mounted on PCB and 
inside enclosure. See 
clause 14. 
N  
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components 
 
8.7 
This clause is void 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
 
 Reinforced 
insulation 
> 0,4 mm (mm)  ....................: 
 
Page of 29