Read JBL GTO 14001 (serv.man3) EMC - CB Certificate online
EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
____________________________________________________________________________________________________________
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 10/F Taiyau Building 181 Johnston Road Wanchai
Tel : 00852-36458129 FAX : 00852-36458092
Report No.:
HL-S07062713
Page 6 of 28
Special stability warning for fixed installation
Adequate instructions
supplied.
supplied.
P
Warning: battery exposure to heat
No battery used
N
Warning: protective film on CRT face
No CRT component
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Appliance coupler is
disconnecting device.
Adequate information
included in “User
instruction”
disconnecting device.
Adequate information
included in “User
instruction”
P
Instructions for permanently connected equipment
No permanently connected
apparatus.
apparatus.
P
6 HAZARDOUS
RADIATION
–
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation.
N
6.1
EN 60065
N
6.2
Laser radiation, emission limits to IEC 60825-1 .....:
No laser radiation.
N
Emission limits under fault conditions .....................:
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
–
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
The mains supply dc 12V
N
Click on the first or last page to see other GTO 14001 (serv.man3) service manuals if exist.