Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) : - Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
- No live parts in apparatus
N
Reinforced
insulation
> 0,4 mm (mm) .................... :
N
Thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.11
Detaching of wires
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
N
Vibration
test
carried out ........................................ :
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
No exclusively be supplied
N