Read JBL SPOT (serv.man3) EMC - CB Certificate online
Page 6 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
18Vdc powered equipment
N
Instructions for permanently connected equipment Not a permanently connected
N
6 HAZARDOUS
RADIATION
N
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation inside the
EUT.
EUT.
N
6.1
EN 60065
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... : No laser radiation inside the
EUT.
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
No such components
N