Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Such parts are considered to 
be bare. 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
No such parts 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No liver parts in apparatus 
8.5 
Class I equipment 
Powered 18 Vd.c. by certified 
adaptor 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 N 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
- Powered 18 Vd.c. by certified 
adaptor 
- No live parts in apparatus 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 N 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
 N 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
 N 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 N 
 
Separation by Class II isolating transformer 
 
Page of 72