SPOT (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 57

Read JBL SPOT (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 56 of 58 
 
Report No.: 
11008507 001 
National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
US National Differences according to CB Bulletin No. 110A, June 2006 
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch 
circuit protection is not suitable. 
Power distribution transformers distributing power 
at 100 volts or more, and rated 10 kVA or more, 
require transformer overcurrent protection. 
3.2 
Wiring methods (terminals, leads, etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC. 
No direct mains connection. 
N/A 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125 percent 
of the rated current of the equipment. 
No direct mains connection. 
N/A 
3.2.3 
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs. 
No direct mains connection. 
N/A 
3.2.5 
Power supply cords are required to be no longer 
than 4.5 m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC. 
No direct mains connection. 
N/A 
3.2.9 
Permanently connected equipment is required to 
have a suitable wiring compartment and wire 
bending space. 
No direct mains connection. 
N/A 
3.3 
Wiring terminals and associated spacings for field 
wiring connections shall comply with CSA C22.2 
No. 0. 
No direct mains connection. 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm²). 
No direct mains connection. 
N/A 
3.3.4 
Terminals for permanent wiring, including 
protective earthing terminals, are required to be 
suitable for U.S./Canadian wire gauge sizes, rated 
125 percent of the equipment rating, and be 
specially marked when specified (1.7.7). 
No direct mains connection. 
N/A 
3.4.2 
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12A, or if the motor 
has a nominal voltage rating greater than 120V, 
or is rated more than 1/3 hp (locked rotor current 
over 43 A) 
No motor control devices. 
N/A 
3.4.8 
Vertically-mounted disconnect switches and 
circuit breakers are required to have the ”on” 
position indicated by the handle in the up position. 
No such switch provided. 
N/A 