US National Differences according to CB Bulletin No. 110A, June 2006
standard supply outlets, receptacles and medium-
base or smaller lampholders if the supply branch
circuit protection is not suitable.
base or smaller lampholders if the supply branch
circuit protection is not suitable.
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require transformer overcurrent protection.
at 100 volts or more, and rated 10 kVA or more,
require transformer overcurrent protection.
3.2
Wiring methods (terminals, leads, etc.) used for
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
the connection of the equipment to the mains
shall be in accordance with the NEC/CEC.
No direct mains connection.
N/A
3.2.1
Power supply cords are required to have
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
attachment plugs rated not less than 125 percent
of the rated current of the equipment.
No direct mains connection.
N/A
3.2.3
Permanent connection of equipment to the mains
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
supply by a power supply cord is not permitted,
except for certain equipment, such as ATMs.
No direct mains connection.
N/A
3.2.5
Power supply cords are required to be no longer
than 4.5 m in length.
than 4.5 m in length.
Flexible power supply cords are required to be
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
compatible with Article 400 of the NEC, and
Tables 11 and 12 of the CEC.
No direct mains connection.
N/A
3.2.9
Permanently connected equipment is required to
have a suitable wiring compartment and wire
bending space.
have a suitable wiring compartment and wire
bending space.
No direct mains connection.
N/A
3.3
Wiring terminals and associated spacings for field
wiring connections shall comply with CSA C22.2
No. 0.
wiring connections shall comply with CSA C22.2
No. 0.
No direct mains connection.
N/A
3.3.3
Wire binding screws are not permitted to attach
conductors larger than 10 AWG (5.3 mm²).
conductors larger than 10 AWG (5.3 mm²).
No direct mains connection.
N/A
3.3.4
Terminals for permanent wiring, including
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
protective earthing terminals, are required to be
suitable for U.S./Canadian wire gauge sizes, rated
125 percent of the equipment rating, and be
specially marked when specified (1.7.7).
No direct mains connection.
N/A
3.4.2
Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12A, or if the motor
has a nominal voltage rating greater than 120V,
or is rated more than 1/3 hp (locked rotor current
over 43 A)
connected equipment with a motor if the
equipment is rated more than 12A, or if the motor
has a nominal voltage rating greater than 120V,
or is rated more than 1/3 hp (locked rotor current
over 43 A)
No motor control devices.
N/A
3.4.8
Vertically-mounted disconnect switches and
circuit breakers are required to have the ”on”
position indicated by the handle in the up position.
circuit breakers are required to have the ”on”
position indicated by the handle in the up position.
No such switch provided.
N/A