Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Canadian National Differences according to CB Bulletin No. 110A, June 2006
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
No battery.
N/A
4.3.12
The maximum quantify of flammable liquid stored
in equipment is required to comply with NFPA 30.
in equipment is required to comply with NFPA 30.
No flammable liquid.
N/A
4.3.13
Equipment with lasers is required to meet Code of
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
N/A
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Not information storage
systems.
systems.
N/A
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m² or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating of
200 or less.
combustible material measuring greater than 0.9
m² or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating of
200 or less.
Not information storage
systems.
systems.
N/A
Annex H
Equipment that produces ionizing radiation is
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
No ionizing radiation.
N/A
Other differences
1.5.1
Components of equipment must be suitable for
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
The acceptance will be based on the following:
A) A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a
Canadian or U.S. component standard will be
checked for correct application and use in
accordance with its specified rating. Where
necessary, it will also be subject to the
applicable tests of the equipment standard.
Canadian or U.S. component standard will be
checked for correct application and use in
accordance with its specified rating. Where
necessary, it will also be subject to the
applicable tests of the equipment standard.
B) A component, which has a CB Test
Certificate for compliance with a relevant IEC
component standard, will be checked for
correct application and use in accordance
with its specified ratings. Where necessary, it
component standard, will be checked for
correct application and use in accordance
with its specified ratings. Where necessary, it
Components are approved,
see component list 1.5.1.
see component list 1.5.1.
P