Report No.:
11008507 001
National Differences
Clause
Requirement − Test
Result – Remark
Verdict
Canadian National Differences according to CB Bulletin No. 110A, June 2006
will also be subject to the applicable tests of
the equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
the equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
C) A component, which has no approval as in A)
or B) above or which is used not in
accordance with its specified ratings, will be
subject to the applicable tests of the
equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
accordance with its specified ratings, will be
subject to the applicable tests of the
equipment standard, and to the applicable
tests of the Canadian and/or U.S. component
or material standard, under the conditions
occurring in the equipment.
D) Some components may require annual re-
testing, which may be carried out by the
manufacturer, CSA International or another
laboratory
manufacturer, CSA International or another
laboratory
2.3.1
For TNV-2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding
42.4 Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mAd.c.
under normal operating conditions.
ringing signals and with voltages exceeding
42.4 Vpeak or 60 Vd.c., the maximum acceptable
current through a 2000 ohm resistor (or greater)
connected across the voltage source with other
loads disconnected is 7.1 mA peak or 30 mAd.c.
under normal operating conditions.
No TNV.
N/A
2.3.2
In the event of a single fault, the limits of 2.2.3
apply to SELV Circuits and accessible conductive
parts.
apply to SELV Circuits and accessible conductive
parts.
No TNV.
N/A
2.6.3.3
When subject to impedance testing, protective
earthing and bonding are required to be subjected
to the additional test conditions specified.
earthing and bonding are required to be subjected
to the additional test conditions specified.
No direct mains connection.
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, writing, marking and
installation instruction requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, writing, marking and
installation instruction requirements.
No direct mains connection.
N/A
4.2.8.1
Enclosures around CRTs with a face diameter of
160mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
160mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No CRT.
N/A
4.3.2
Equipment with handles is required to comply with
special loading tests.
special loading tests.
No handles.
N/A
5.1.8.3
Equipment intended to receive telecommunication
ringing signals is required to comply with a special
touch current measurement tests.
ringing signals is required to comply with a special
touch current measurement tests.
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No used.
N/A