Report No.:
11008507 001
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
N/A
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
P
4.5.1
Maximum temperatures
See appended table 4.5.1.
P
Normal load condition per Annex L.....................:
See 1.6.2.
P
4.5.2
Resistance to abnormal heat
N/A
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings.
P
Dimensions (mm) ..............................................:
4.6.2
Bottoms of fire enclosures
No openings.
P
Construction of the bottom .................................:
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (°C)/time (weeks) ......:
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
See below.
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
Use of materials with the
required flammability classes.
required flammability classes.
P
Method 2, application of all of simulated fault
condition tests
condition tests
Method 1 used.
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
See 4.7.2.2.
N/A