Read JBL SPOT (serv.man2) EMC - CB Certificate online
Page 11 of 58
Report No.:
11008507 001
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Instructions when protection relies on building
installation
installation
N/A
2.7.2
Faults not covered in 5.3
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ......... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel .............................. :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ............................................. :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Only SELV circuits inside the unit. (See also sub clause 5.3.4)
Only SELV circuits inside the unit. (See also sub clause 5.3.4)
P
2.9.1
Properties of insulating materials
P
2.9.2
Humidity conditioning
N/A
Humidity (%) ....................................................... :
Temperature (°C) ................................................ :
2.9.3
Grade of insulation
P
2.10
Clearances, creepage distances and distances through insulation
Only SELV circuits inside the unit. (See also sub clause 5.3.4)
Only SELV circuits inside the unit. (See also sub clause 5.3.4)
N/A
2.10.1
General
N/A
2.10.2
Determination of working voltage
N/A
2.10.3
Clearances
N/A
2.10.3.1
General
N/A
Click on the first or last page to see other SPOT (serv.man2) service manuals if exist.