Read JBL SPOT (serv.man2) EMC - CB Certificate online
Page 8 of 58
Report No.:
11008507 001
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
2
PROTECTION FROM HAZARDS
The unit is supplied by SELV and energy is below 240VA. No risk of electrical shock
or energy hazards.
The unit is supplied by SELV and energy is below 240VA. No risk of electrical shock
or energy hazards.
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
P
2.1.1.1
Access to energized parts
N/A
Test by inspection ............................................... :
N/A
Test with test finger ............................................. :
N/A
Test with test pin ................................................. :
N/A
Test with test probe ............................................ :
N/A
2.1.1.2
Battery compartments ........................................ :
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance (mm) through insulation
distance (mm) through insulation
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ................................................... :
P
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Time-constant (s); measured voltage (V) ............ :
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
2.2
SELV circuits
P
2.2.1
General requirements
See below.
P
2.2.2
Voltages under normal conditions (V) ................. : Between any conductor of the
SELV circuits 42.4Vpeak or
60Vdc are not exceeded.
60Vdc are not exceeded.
P
2.2.3
Voltages under fault conditions (V)...................... : Single fault did not cause
excessive voltage in accessible
SELV circuits. Limits of
71Vpeak and 120Vdc were not
exceed and SELV limits not for
longer than 0.2s.
SELV circuits. Limits of
71Vpeak and 120Vdc were not
exceed and SELV limits not for
longer than 0.2s.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
Class III equipment.
N/A
2.2.3.2
Separation by earthed screen (method 2)
Class III equipment.
N/A
2.2.3.3
Protection by earthing of the SELV circuit
(method 3)
(method 3)
Class III equipment.
N/A
Click on the first or last page to see other SPOT (serv.man2) service manuals if exist.