Page 9 of 38
Report No. : 12-1330-0044
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
The input current is small than
0.2A.
P
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered.
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
The apparatus was subjected
of humidity treatment for 168
hrs at 40
of humidity treatment for 168
hrs at 40
o
C and R.H. of 95%.
After the tests, the tests of 10.3
are made and pass.
are made and pass.
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
N/A
8.5
Class I equipment
The apparatus is Class II
apparatus.
apparatus.
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
See below.
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Hazardous live parts to
accessible parts are separated
by either reinforced or double
insulation.
accessible parts are separated
by either reinforced or double
insulation.
P