Report No. : 12-1330-0044 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The isolating transformer has 
been tested within this report 
and complying with subclause 
14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Hazardous live parts and 
accessible parts separated by 
one capacitor, which used was 
certified as Y1 capacitor 
according to IEC 60384-14. 
8.7 
This clause is void  
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
 
N/A 
 
Reinforced insulation > 0,4 mm (mm)  .................... : 
The photo coupler and internal 
plastic enclosure which were 
provided distance through 
insulation of minimum 0.4 mm. 
See appended table 14 for 
details. 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
The thin sheet materials of 
polyester tape used in 
transformers. 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
(see appended table 13) 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 
N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
All internal wires with only 
basic isolation are routed so 
that they are not close to any 
live bare components. 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
All internal hazardous live parts 
are separated by double or 
reinforced insulation form 
conductors connected to 
accessible parts. 
Page of 78