SOUNDFLY AIR - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL SOUNDFLY AIR EMC - CB Certificate online

 
Page 12 of  38 
Report No. : 12-1330-0044 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table for detail. 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
See appended table for detail. 
 
c) Discharge not exceeding 45 
μC  
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access with test finger or 
test probe to any parts bearing 
hazardous voltage. 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No hazardous live parts can be 
touched by the metal test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
The test probe did not become 
hazardous live parts after test. 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
No access to any parts at 
hazardous voltage. 
9.1.5 
Pre‑ set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
The voltage of pins or contacts 
for the mains plug no exceed 
hazardous live after 2 seconds. 
Test voltage: 264V/60Hz, 
Measured voltage: 30V. 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
See below. 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Hazardous live part is not 
accessible. 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Hazardous live part is not 
accessible. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N force applied. Hazardous 
live part is not accessible. 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 
Insulation requirements 
Page of 78