SB 300 (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 7

Read JBL SB 300 (serv.man6) EMC - CB Certificate online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 7 of 97
 
 
2. SUMMARY OF TEST RESULTS 
 
Test procedures according to the technical standards: 
EMC Emission                           
Standard 
Test Item 
Limit 
Judgment  Remark
Mains Terminal Disturbance 
Voltage Test 
------ PASS  
Disturbance Power Test 
------ 
PASS 
 
Radiated Disturbance Test 
------ 
N/A 
 
EN 55013: 2001+A1: 
2003+A2: 2006
 
Disturbance Voltage at the 
Antenna Terminals Test 
------ N/A  
EN 61000-3-2:2006   
Harmonic Current Emission 
Class A
 
PASS  
EN 61000-3-3:2008 
Voltage Fluctuations & Flicker
------ 
PASS 
 
EMC Immunity 
(EN 55020: 2007)
 
Section 
Test Item 
Performance 
Criteria 
Judgment Remark
Input immunity 
 (S1) 
------ N/A 
 
Immunity against 
RFI voltages (S2a) 
------ PASS 
 
Immunity against 
RFI currents (S2b) 
------ N/A 
 
Immunity against radiated RFI 
(S3) 
------ PASS 
 
Screening effectiveness   
(S4) 
------ N/A 
 
Immunity to electromagnetic 
fields Keyed Carrier   
(S5) 
------ PASS 
 
EN 55020 
(2007) 
Immunity against radiated RFI 
(S6) 
------ N/A 
 
IEC 61000-4-2 
(2008) 
Electrostatic Discharge 
PASS 
 
IEC 61000-4-3 
(2006+A1:2007+A2:2010) 
RS electromagnetic field 
PASS 
 
IEC 61000-4-4 
(2004+A1:2010) 
Fast transients 
PASS 
 
NOTE: 
 
(1)” N/A” denotes test is not applicable in this Test Report 
 
 
 
 
 
 
 
 
 
 
Page of 97