2. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
EMC Emission
Standard
Test Item
Limit
Judgment Remark
Mains Terminal Disturbance
Voltage Test
------ PASS
Disturbance Power Test
------
PASS
Radiated Disturbance Test
------
N/A
EN 55013: 2001+A1:
2003+A2: 2006
Disturbance Voltage at the
Antenna Terminals Test
------ N/A
EN 61000-3-2:2006
Harmonic Current Emission
Class A
PASS
EN 61000-3-3:2008
Voltage Fluctuations & Flicker
------
PASS
EMC Immunity
(EN 55020: 2007)
Section
Test Item
Performance
Criteria
Judgment Remark
Input immunity
(S1)
------ N/A
Immunity against
RFI voltages (S2a)
------ PASS
Immunity against
RFI currents (S2b)
------ N/A
Immunity against radiated RFI
(S3)
------ PASS
Screening effectiveness
(S4)
------ N/A
Immunity to electromagnetic
fields Keyed Carrier
(S5)
------ PASS
EN 55020
(2007)
Immunity against radiated RFI
(S6)
------ N/A
IEC 61000-4-2
(2008)
Electrostatic Discharge
B
PASS
IEC 61000-4-3
(2006+A1:2007+A2:2010)
RS electromagnetic field
A
PASS
IEC 61000-4-4
(2004+A1:2010)
Fast transients
B
PASS