SB 300 (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 8

Read JBL SB 300 (serv.man6) EMC - CB Certificate online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 8 of 97
 
 
2.1 TEST FACILITY 
  The test facilities used to collect the test data in this report is SR01/SR03  at the location of 
No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792. 
 
2.2 MEASUREMENT UNCERTAINTY   
 
Where relevant, the following measurement uncertainty levels have been estimated 
for tests performed on the EUT as specified in CISPR 16-4-2: 
 
The reported uncertainty of measurement y  ±  U,where expended uncertainty is based on a 
standard uncertainty multiplied by a coverage factor of    k=2,providing a level of confidence of 
approximately 95 %。 
 
A. Mains Terminal Disturbance Voltage Test : 2.44 dB 
 
B. Radiated Disturbance Test : 
 
Test Site  Method
Measurement Frequency 
Range 
Ant. 
H / V
U,(dB) 
NOTE 
SR01 
 
30MHz ~ 300MHz 
 
2.64 
 
SR03  
 
 2.85 
 
 
  C. Harmonic/ Flicker Measurement : 
 
Test item 
NOTE 
IEC 61000-3-2  Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
 
 
IEC 61000-3-3  Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
 
 
       
  D. Immunity Measurement : 
 
Test item 
NOTE 
IEC 61000-4-2 
Voltage: 1.6%; Timing: 2.8% 
 
IEC 61000-4-3 
2.66 dB 
 
IEC 61000-4-4 
Voltage: 1.6%; Timing: 2.8%; Frequency: 2.8x10
-10  
 
 
       
 
Page of 97
Display