Read JBL SB 100 (serv.man3) EMC - CB Certificate online
Page 3 of 68
Report No.: 350-120154AX
TRF No. IEC60065K
List of Attachments (including a total number of pages in each attachment):
-
Manufacturer’s Declaration: 1 sheet
-
Photograph: 8 sheets / 15 Figs
Summary of testing:
1) The sample tested complies with the requirements of the test specification.
2) The subject models CINEMA SB100 and CINEMA STV100 are same except for model designation.
Unless otherwise specified, all tests were performed on model CINEMA SB100.
3) As for Power Transformer (T5311), multi factories will produce them as alternative use. Since it was
same to each other on construction and electrical characteristics, the difference of factory did not affect
safety aspects.
Unless otherwise specified, all tests were conducted on the following transformer as representative.
T5311: SUNSHINE Electronics Co., LTD / BCK-BH140
safety aspects.
Unless otherwise specified, all tests were conducted on the following transformer as representative.
T5311: SUNSHINE Electronics Co., LTD / BCK-BH140
4) Following symbols and abbreviations are used in this test report.
S/C= Short-Circuit
O/C= Open-Circuit
MT= Mains Transformer TW= Transformer Winding (measured by resistance method)
TC= Transformer Core TP= Thermal Protector
NH= No Hazard Occurred
TC= Transformer Core TP= Thermal Protector
NH= No Hazard Occurred
NFR= No Further Results existed
+ = total overheated areas of the printed board(s) are not larger than 2 cm².
LC= Lead Connection on the printed board
PCB= Printed Circuit Board
IE= Inside of Enclosure OE= Outside of Enclosure
KH= Knob, Handle
LC= Lead Connection on the printed board
PCB= Printed Circuit Board
IE= Inside of Enclosure OE= Outside of Enclosure
KH= Knob, Handle
PW= Primary Wire
IB= Insulating Barrier
E = Emitter
C = Collector
B = Base
* = Determined by the method specified in Note f to Table 3.
Tests performed (name of test and test clause):
Full tests
Full tests
Testing location: see page 2 (Testing procedure
and testing location)
and testing location)
Summary of compliance with National Differences
List of countries addressed: EN, AU, NZ, KR, MY, UA, JP
List of countries addressed: EN, AU, NZ, KR, MY, UA, JP
SG, KE, BR, RU (no national differences in CB-Bulletin)
Click on the first or last page to see other SB 100 (serv.man3) service manuals if exist.