RADIAL (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 4

Read JBL RADIAL (serv.man5) EMC - CB Certificate online

 
Page 3 of 49 
Report No. 152949 
 
 
TRF No. IEC60950_1B 
 
 
 
List of Attachments (including a total number of pages in each attachment):  
National differences:  Australia (8 pages), Canada (6 pages), China (1 page), Israel (1 page),  
Japan (14 pages), Korea (1 page), Singapore (2 pages), Ukraine (1 page), USA (7 pages).
 
 
 
Summary of testing 
General, Main Unit, 1.5.4, 2.5, 3.2.1, 4.7.
 
The external power supply was not evaluated as 
part of this report.  An external 24V SELV Limited 
Power Source (LPS) approved to IEC 60950-1(2
nd
 
edition) shall be provided. The external power 
supply shall comply with the national regulations of 
the countries in which the appliance is to be sold.
 
1.7.2 Safety instructions, required markings 
regarding use of a specified power supply 
Class III Equipment with an enclosure made of HB-
Material, using a non-special connector for the DC 
input must have a marking stating the 
manufacturer and model number of the power 
supply to be used.  Marking is provided. 
1.7.12; Language of safety markings/instruction 
Instructions and equipment markings are to be 
provided in a language that is acceptable in the 
country in which the equipment is to be sold. 
4.5.1; Thermal requirements 
Equipment under test is class III equipment. 
Several components were monitored while the unit 
was operation normal Max. loading configuration.   
4.5.2, Annex L; Normal load condition per Annex L 
Normal operation is considered 1/8th of maximum 
undistorted power. Non-clipping was determined 
using a 1 KHz sinusoidal signal input. For 
maximum normal operation, 1/8th of the non-
clipping amplitude was used with a filtered pink 
noise input signal. 
5.3.1; Abnormal operation and fault conditions 
Equipment under test is class III equipment. Only 
the fault test in appended table 5.3 was considered 
necessary.  Refer to appended table 5.3 
 
 
Tests performed (name of test and test clause): 
Testing location: See page 2. 
1.6.2; Input current
 
1.7.11; Durability test 
4.1; Physical requirements 
4.5.1; Temperature test 
5.3; Abnormal operation and fault conditions
 
 
 
 