Read JBL RADIAL (serv.man5) EMC - CB Certificate online
Page 6 of 49
Report No. 152949
TRF No. IEC60950_1B
Test item particulars ................................................... :
Equipment mobility..................................................... : [X] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................ : [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition .................................................... : [X] continuous
Normal load:
Max. Undistorted with sign wave signal was 4 W,
reduced to 1/8th Max. with filtered pink noise per
IEC/EN 60065 for maximum normal load.
Refer to Summary of Testing.
[] rated operating / resting time:
Max. Undistorted with sign wave signal was 4 W,
reduced to 1/8th Max. with filtered pink noise per
IEC/EN 60065 for maximum normal load.
Refer to Summary of Testing.
[] rated operating / resting time:
Access location ......................................................... : [X] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [X] OVC I [] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains
supply values ............................................................ :
supply values ............................................................ :
N/A
Tested for IT power systems .................................... : [] Yes [X] No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : [] Class I [] Class II [X] Class III
[] Not classified
Considered current rating of protective device as
part of the building installlation (A) ........................... :
part of the building installlation (A) ........................... :
N/A
Pollution degree (PD) ............................................... : [] PD 1 [X] PD 2 [] PD 3
IP protection class .................................................... : Minimum IP 20 (not evaluated for ingress of water)
Altitude during operation (m) .................................... : Normal Home and office <2000m
Altitude of test laboratory (m) .................................... : 10m, sea level
Mass of equipment (kg) ............................................ : 2.2 kg (representative of all models)
Dimension: 30.5mm diameter by 27mm tall
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A (or N)
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ............................................ : 2010-06
Date(s) of performance of tests .................................... : 2010-06 – 2010-07