Read JBL RADIAL (serv.man5) EMC - CB Certificate online
Page 11 of 49
Report No. 152949
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.7.2
Safety instructions and marking
Provided with marking
regarding use of specified
power supply, refer to copy of
marking plate.
regarding use of specified
power supply, refer to copy of
marking plate.
P
1.7.2.1 General
P
1.7.2.2
Disconnect devices
Class III equipment.
N/A
1.7.2.3
Overcurrent protective device
Class III equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
Class III equipment. Supplied
from a LPS.
from a LPS.
N/A
1.7.2.6 Ozone
No
Ozone
generator.
N/A
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment .......................... :
No standard power outlet.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
No fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals .......... :
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
Refer below:
P
1.7.8.1
Identification, location and marking ...................... :
No controls or figures
affecting safety provided.
affecting safety provided.
N/A
1.7.8.2
Colours ................................................................ :
No controls or indicators us
color.
color.
N/A
1.7.8.3
Symbols according to IEC 60417 ......................... :
There are no switches in the
equipment. Control is marked
with “+” and “-“.
equipment. Control is marked
with “+” and “-“.
P
1.7.8.4
Markings using figures ....................................... :
N/A
1.7.9
Isolation of multiple power sources ..................... :
Class III equipment. Single
connection.
connection.
N/A
1.7.10
Thermostats and other regulating devices .......... :
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12 Removable
parts
No
removable
parts.
P
Click on the first or last page to see other RADIAL (serv.man5) service manuals if exist.