RADIAL (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL RADIAL (serv.man5) EMC - CB Certificate online

 
Page 11 of 49 
Report No. 152949 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
1.7.2 
Safety instructions and marking 
Provided with marking 
regarding use of specified 
power supply, refer to copy of 
marking plate. 
1.7.2.1 General 
 
1.7.2.2 
Disconnect devices 
Class III equipment. 
N/A 
1.7.2.3 
Overcurrent protective device 
Class III equipment. 
N/A 
1.7.2.4 
IT power distribution systems 
Class III equipment. 
N/A 
1.7.2.5 
Operator access with a tool 
Class III equipment. Supplied 
from a LPS. 
N/A 
1.7.2.6 Ozone 
No 
Ozone 
generator. 
N/A 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation. 
N/A 
1.7.4 
Supply  voltage  adjustment   ................................... : 
No  voltage  selector. 
N/A 
 
Methods and means of adjustment; reference to 
installation  instructions   ......................................... : 
 N/A 
1.7.5 
Power outlets on the equipment  .......................... : 
No standard power outlet. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
No fuses. 
N/A 
1.7.7 
Wiring terminals 
Class III equipment. 
N/A 
1.7.7.1 
Protective earthing and bonding terminals  .......... : 
 
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
Refer below: 
1.7.8.1 
Identification, location and marking  ...................... : 
No controls or figures 
affecting safety provided. 
N/A 
1.7.8.2 
Colours   ................................................................ : 
No controls or indicators us 
color. 
N/A 
1.7.8.3 
Symbols according to IEC 60417 ......................... : 
There are no switches in the 
equipment. Control is marked 
with “+” and “-“.  
1.7.8.4 
Markings using figures   ....................................... : 
 
N/A 
1.7.9 
Isolation of multiple power sources  ..................... : 
Class III equipment. Single 
connection. 
N/A 
1.7.10 
Thermostats and other regulating devices  .......... : 
No thermostats or other 
regulating devices. 
N/A 
1.7.11 
Durability 
The marking withstands 
required tests. 
1.7.12 Removable 
parts 
No 
removable 
parts. 
Page of 102
Display