RADIAL MICRO (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 117

Read JBL RADIAL MICRO (serv.man2) EMC - CB Certificate online

 
 
 
Appendix 4 
Page 3 of 3 
ST-06153 
 
 
 
 
 
 
Static damp heat test:  
Db (12 + 12 h cycle), 95 % R.H., lower 
temperature 25 
± 3 °C and upper temperature 40 
°C. After the test, It shall be complied with  
clause 2.13.2 (e) insulation resistance test,  
clause 2.13.3 high voltage test, and  
clause 2.13.13.6 abrasion test 
 P 
 
Lower temperature test:  
−15 ± 2 °C for 24 h. After the test, It shall be 
complied with  
clause 2.13.2 (e) insulation resistance test,  
clause 2.13.3 high voltage test, and  
clause 2.13.13.6 abrasion test 
 P 
 
Impact test at low temperature:  
−15 ± 2 °C for 24 h, falling weight mass 100 ± 1 
g, falling height 100 mm, four impacts. 
 P 
 Abrasion 
test: 
4 N, 10 000 times in each direction (20 000 
movements) at a rate of 30 movements per 
minute. 
 P 
J2.2.6.7 
Torque to socket-outlet test 
Plug shall not impose undue strain on fixed 
socket-outlets, limit 
≤ 0.25 Nm 
Measured max. 0.06 Nm 
P - Pass; N/A - Not applicable; Info - Information only