Read JBL RADIAL MICRO (serv.man2) EMC - CB Certificate online
Appendix 4
Page 3 of 3
ST-06153
Static damp heat test:
Db (12 + 12 h cycle), 95 % R.H., lower
temperature 25
temperature 25
± 3 °C and upper temperature 40
°C. After the test, It shall be complied with
clause 2.13.2 (e) insulation resistance test,
clause 2.13.3 high voltage test, and
clause 2.13.13.6 abrasion test
P
Lower temperature test:
−15 ± 2 °C for 24 h. After the test, It shall be
complied with
complied with
clause 2.13.2 (e) insulation resistance test,
clause 2.13.3 high voltage test, and
clause 2.13.13.6 abrasion test
P
Impact test at low temperature:
−15 ± 2 °C for 24 h, falling weight mass 100 ± 1
g, falling height 100 mm, four impacts.
g, falling height 100 mm, four impacts.
P
Abrasion
test:
4 N, 10 000 times in each direction (20 000
movements) at a rate of 30 movements per
minute.
movements) at a rate of 30 movements per
minute.
P
J2.2.6.7
Torque to socket-outlet test
Plug shall not impose undue strain on fixed
socket-outlets, limit
socket-outlets, limit
≤ 0.25 Nm
Measured max. 0.06 Nm
P
P - Pass; N/A - Not applicable; Info - Information only
Click on the first or last page to see other RADIAL MICRO (serv.man2) service manuals if exist.