Read JBL RADIAL MICRO (serv.man2) EMC - CB Certificate online
Appendix 6
Page 1 of 1
ST-06153
Equipment’s combined with two-pole plug (Class II)
Supplementary tests on plug portion are according to ANSI/UL 1310
Supplementary tests on plug portion are according to ANSI/UL 1310
Clause Requirement - Test
Result-Remark
Comply
1 Dimensions
1.1
Checked according to figure C1.1 of ANSI/UL
1681
1681
P
1.2
Checked according to figure 5.1, sub-clauses
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996
P
2
Direct Plug-In Blade Secureness Test
2.1
Pull test (89 N / 20 lb, 2 min.); clause 41 of
ANSI/UL 1310-1996
ANSI/UL 1310-1996
Blades are not loosened
P
3
Direct Plug-In Security of Input Contacts Test
3.1
Push test of each blade (133 N / 30 lb, 1
min.); clause 42 of ANSI/UL 1310-1996
min.); clause 42 of ANSI/UL 1310-1996
Blades are not loosened
P
3.2
Push test of all blades (178 N / 40 lb, 1 min.);
clause 42 of ANSI/UL 1310-1996
clause 42 of ANSI/UL 1310-1996
Blades are not loosened
P
4
Rod Pressure on Direct Plug-in Units
4.1
Outer surface of the unit rod pressure test (89N / 20lb, 1 min); sub-clause
44.4 of ANSI/UL 1310-1996
44.4 of ANSI/UL 1310-1996
P
Live part shall not become user accessible
P
Hazardous part shall not become user
accessible
accessible
P
Voltage between dead metal and earth
ground shall not exceed 42.4 Vpeak..............:
ground shall not exceed 42.4 Vpeak..............:
N/A
Leakage between dead metal and earth
ground shall not exceed 7.07 mApeak...........:
ground shall not exceed 7.07 mApeak...........:
N/A
5
Resistance to Crushing on Direct Plug-in Units
5.1
Enclosure crushing test (334 N / 75 lb, 1
min.); sub-clause 44.5 of ANSI/UL 1310-1996
min.); sub-clause 44.5 of ANSI/UL 1310-1996
There is no shattering,
cracking or other damage to
the enclosure that will
expose internal wiring or live
parts
cracking or other damage to
the enclosure that will
expose internal wiring or live
parts
P
P - Pass; N/A - Not applicable
Click on the first or last page to see other RADIAL MICRO (serv.man2) service manuals if exist.