RADIAL MICRO (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 119

Read JBL RADIAL MICRO (serv.man2) EMC - CB Certificate online

 
 
 
Appendix 6 
Page 1 of 1 
ST-06153 
 
 
 
 
 
Equipment’s combined with two-pole plug (Class II) 
Supplementary tests on plug portion are according to ANSI/UL 1310 
 
Clause  Requirement - Test 
Result-Remark 
Comply 
 
 
 
 
1 Dimensions 
 
1.1 
Checked according to figure C1.1 of ANSI/UL 
1681 
 P 
1.2 
Checked according to figure 5.1, sub-clauses 
5.11, 5.12 and 5.13 of ANSI/UL 1310-1996  
 P 
Direct Plug-In Blade Secureness Test 
 
2.1 
Pull test (89 N / 20 lb, 2 min.); clause 41 of 
ANSI/UL 1310-1996 
Blades are not loosened 
Direct Plug-In Security of Input Contacts Test 
 
3.1 
Push test of each blade (133 N / 30 lb, 1 
min.); clause 42 of ANSI/UL 1310-1996 
Blades are not loosened 
3.2 
Push test of all blades (178 N / 40 lb, 1 min.); 
clause 42 of ANSI/UL 1310-1996 
Blades are not loosened 
Rod Pressure on Direct Plug-in Units 
 
4.1 
Outer surface of the unit rod pressure test (89N / 20lb, 1 min); sub-clause 
44.4 of ANSI/UL 1310-1996  
 
Live part shall not become user accessible 
 
 
Hazardous part shall not become user 
accessible 
 P 
 
Voltage between dead metal and earth 
ground shall not exceed 42.4 Vpeak..............:
 N/A 
 
Leakage between dead metal and earth 
ground shall not exceed 7.07 mApeak...........:
 N/A 
Resistance to Crushing on Direct Plug-in Units 
 
5.1 
Enclosure crushing test (334 N / 75 lb, 1 
min.); sub-clause 44.5 of ANSI/UL 1310-1996
There is no shattering, 
cracking or other damage to 
the enclosure that will 
expose internal wiring or live 
parts 
P - Pass; N/A - Not applicable 
 