Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
Test with test finger ............................................ :
N/A
Test with test pin ................................................ :
N/A
Test with test probe ............................................ :
N/A
2.1.1.2 Battery
compartments
........................................ :
No TNV circuits in the
equipment.
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV.
N/A
Working
voltage
(V);
minimum distance (mm)
through insulation
—
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment. No
hazardous voltage supplied to
equipment.
hazardous voltage supplied to
equipment.
N/A
2.1.1.5 Energy
hazards
.................................................. :
Class III equipment for supply
from LPS source. No energy
hazard in operator access area.
from LPS source. No energy
hazard in operator access area.
N/A
2.1.1.6 Manual
controls
No shafts of knobs etc. at ELV or
hazardous voltage.
hazardous voltage.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment. Not intended
for connection to AC mains
supply.
for connection to AC mains
supply.
N/A
Time-constant (s); measured voltage (V) ........... :
—
2.1.2
Protection in service access areas
Class III equipment. No
hazardous voltage supplied to
equipment. No bare parts at
hazardous energy level.
hazardous voltage supplied to
equipment. No bare parts at
hazardous energy level.
N/A
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2.2 SELV
circuits
P
2.2.1 General
requirements
Class III equipment intended to
be power from separately
certified SELV source.
SELV limits are not exceeded
under normal condition and after
a single fault.
be power from separately
certified SELV source.
SELV limits are not exceeded
under normal condition and after
a single fault.
P
2.2.2
Voltages under normal conditions (V)................. :
Within SELV limits.
P
2.2.3
Voltages under fault conditions (V)..................... :
Within SELV limits. Powered by
Limited Power Source
Limited Power Source
.
P
2.2.3.1
Separation by double insulation or reinforced
insulation (method 1)
insulation (method 1)
N/A
2.2.3.2
Separation by earthed screen (method 2)
N/A