ON TOUR XTB (serv.man8) - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL ON TOUR XTB (serv.man8) EMC - CB Certificate online

 
 
- Page 13 of 57 - 
 
 
www.nemko.com
 
Report No.  111547 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict
 
1.6 Power 
interface 
N/A
 
1.6.1 
AC power distribution systems 
Class III equipment, not 
connected to mains supply.  
N/A
 
1.6.2 Input 
current 
See appended table 1.6.2. 
N/A
 
1.6.3 
Voltage limit of hand-held equipment 
Class III equipment.
 
N/A
 
1.6.4 Neutral 
conductor 
 
Class III equipment.
 
N/A
 
 
1.7 
Markings and instructions 
P
 
1.7.1 
Power rating  
Class III equipment not for direct 
connection to a mains supply. No 
electrical rating markings 
required. 
 
P
 
 
Rated voltage(s) or voltage range(s) (V)  ........... : 
12Vdc 
N/A
 
 
Symbol for nature of supply, for d.c. only ........... : 
Not for connection to D.C. mains 
supply. 
N/A
 
 
Rated frequency or rated frequency range (Hz)  : 
 
N/A
 
 
Rated current (mA or A) ..................................... : 
1.25A 
N/A
 
 
Manufacturer’s name or trademark or 
identification mark  .............................................. : 
 
P
 
 
Type/model or type reference............................. : 
On Tour XTB 
P
 
 
Symbol for Class II equipment only  ................... : 
Class III equipment. 
N/A
 
 Other 
symbols 
.................................................... : 
The additional marking does not 
give rise to misunderstandings.
 
P
 
 Certification 
marks 
............................................. : 
Refer to Copy of marking plate.
 
P
 
1.7.2 Safety 
instructions 
Provided with marking regarding 
use of specified power supply, 
refer to copy of marking plate.
 
P
 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation.
 
N/A
 
1.7.4 Supply 
voltage 
adjustment 
................................. : 
No voltage selector.
 
N/A
 
1.7.5 
Power outlets on the equipment  ........................ : 
No standard power outlet.
 
N/A
 
1.7.6 Fuse 
identification 
.............................................. : 
 
N/A
 
1.7.7 Wiring 
terminals 
Class III equipment.
 
N/A
 
1.7.7.1 
Protective earthing and bonding terminals  ........ :   
N/A
 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A
 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A
 
Page of 86