Read JBL ON TOUR XTB (serv.man8) EMC - CB Certificate online
- Page 13 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.6 Power
interface
N/A
1.6.1
AC power distribution systems
Class III equipment, not
connected to mains supply.
connected to mains supply.
N/A
1.6.2 Input
current
See appended table 1.6.2.
N/A
1.6.3
Voltage limit of hand-held equipment
Class III equipment.
N/A
1.6.4 Neutral
conductor
Class III equipment.
N/A
1.7
Markings and instructions
P
1.7.1
Power rating
Class III equipment not for direct
connection to a mains supply. No
electrical rating markings
required.
connection to a mains supply. No
electrical rating markings
required.
P
Rated voltage(s) or voltage range(s) (V) ........... :
12Vdc
N/A
Symbol for nature of supply, for d.c. only ........... :
Not for connection to D.C. mains
supply.
supply.
N/A
Rated frequency or rated frequency range (Hz) :
N/A
Rated current (mA or A) ..................................... :
1.25A
N/A
Manufacturer’s name or trademark or
identification mark .............................................. :
identification mark .............................................. :
P
Type/model or type reference............................. :
On Tour XTB
P
Symbol for Class II equipment only ................... :
Class III equipment.
N/A
Other
symbols
.................................................... :
The additional marking does not
give rise to misunderstandings.
give rise to misunderstandings.
P
Certification
marks
............................................. :
Refer to Copy of marking plate.
P
1.7.2 Safety
instructions
Provided with marking regarding
use of specified power supply,
refer to copy of marking plate.
use of specified power supply,
refer to copy of marking plate.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4 Supply
voltage
adjustment
................................. :
No voltage selector.
N/A
1.7.5
Power outlets on the equipment ........................ :
No standard power outlet.
N/A
1.7.6 Fuse
identification
.............................................. :
N/A
1.7.7 Wiring
terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........ :
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
Click on the first or last page to see other ON TOUR XTB (serv.man8) service manuals if exist.