Read JBL ON TOUR XTB (serv.man8) EMC - CB Certificate online
- Page 14 of 57 -
www.nemko.com
Report No. 111547
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.8 Controls
and
indicators
Unit is provided with a secondary
push power switch.
push power switch.
P
1.7.8.1
Identification, location and marking ................... :
N/A
1.7.8.2 Colours
............................................................... :
N/A
1.7.8.3 Symbols
............................................................ :
Secondary power push button
marked with the standby symbol
(IEC 60417, No. 5010).
marked with the standby symbol
(IEC 60417, No. 5010).
P
1.7.8.4
Markings using figures ...................................... :
N/A
1.7.9
Isolation of multiple power sources .................... :
Class III equipment for supply
from a SELV, LPS power source.
from a SELV, LPS power source.
N/A
1.7.10
IT power distribution systems
Class III equipment for supply
from a SELV, LPS power source.
from a SELV, LPS power source.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12 Language
........................................................... :
Instructions and markings shall
be in a language acceptable for
the country where the equipment
is to be used.
be in a language acceptable for
the country where the equipment
is to be used.
—
1.7.13 Durability
The marking withstands required
tests.
tests.
P
1.7.14 Removable
parts
No marking is placed on
removable parts.
removable parts.
N/A
1.7.15 Replaceable
batteries
Equipment can be powered by
consumer grade AA, alkaline
batteries, which are considered
inherently safe. Refer to
Summary of Testing and
appended table 4.3.8.
consumer grade AA, alkaline
batteries, which are considered
inherently safe. Refer to
Summary of Testing and
appended table 4.3.8.
P
Language ............................................................ :
English
—
1.7.16
Operator access with a tool ................................ :
No operator access with a tool.
N/A
1.7.17
Equipment for restricted access locations .......... :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2 PROTECTION
FROM
HAZARDS
N/A
2.1
Protection from electric shock and energy hazards
N/A
2.1.1
Protection in operator access areas
Refer below:
N/A
2.1.1.1
Access to energized parts
Class III equipment. No
hazardous voltage or energy
supplied to equipment.
hazardous voltage or energy
supplied to equipment.
N/A
Test by inspection .............................................. :
N/A