ON TIME 200ID - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL ON TIME 200ID EMC - CB Certificate online

 
 
<12014165 001> 
 
 
Page 11 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No such hazardous device. 
N/A 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
No ventilation holes. 
N/A 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
No such terminal. 
N/A 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 
N/A 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
After 2 seconds, the measured voltage 
across the main terminals is 8 V (no o/p 
load applied, supply voltage was 264 V 
r.m.s.). 
Capacitance provided: CX1=0,33 µF, 
Discharge resistance provided: 
R1=R2=1MΩ 
 
If C is not greater than 0,1 µF no test needed 
The nominal capacitance across the 
mains poles is exceeding 0,1µF. 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool for 
5 s (100 or 250 N)  ................................................... : 
100N 
9.2 
No hazard 2s after removing a cover by hand 
The enclosure of the appliance is fixed 
by ultrasonic welding, no risk of 
removing by hand. 
N/A 
 
 
 
 
10 
INSULATION REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
Mains supply plug and input/output 
terminals were subjected to 50 
discharges. 
10.2 
Humidity treatment 48 h or 120 h  ........................... :  Performed for 120h at temperature 
between 40 °C and a relative humidity 
between 93%. 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
Page of 91