IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No such hazardous device.
N/A
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No ventilation holes.
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
No such terminal.
N/A
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
N/A
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
After 2 seconds, the measured voltage
across the main terminals is 8 V (no o/p
load applied, supply voltage was 264 V
r.m.s.).
across the main terminals is 8 V (no o/p
load applied, supply voltage was 264 V
r.m.s.).
Capacitance provided: CX1=0,33 µF,
Discharge resistance provided:
R1=R2=1MΩ
R1=R2=1MΩ
P
If C is not greater than 0,1 µF no test needed
The nominal capacitance across the
mains poles is exceeding 0,1µF.
mains poles is exceeding 0,1µF.
N/A
9.1.7
Enclosure sufficiently resistant to external force
P
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ................................................... :
5 s (100 or 250 N) ................................................... :
100N
P
9.2
No hazard 2s after removing a cover by hand
The enclosure of the appliance is fixed
by ultrasonic welding, no risk of
removing by hand.
by ultrasonic welding, no risk of
removing by hand.
N/A
10
INSULATION REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Mains supply plug and input/output
terminals were subjected to 50
discharges.
terminals were subjected to 50
discharges.
P
10.2
Humidity treatment 48 h or 120 h ........................... : Performed for 120h at temperature
between 40 °C and a relative humidity
between 93%.
between 93%.
P
10.3
Insulation resistance and dielectric strength
(see appended table)
P