<12014165 001> 
 
 
Page 10 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
No mains socket-outlet. 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
No such parts that hazardous live parts 
are rendered accessible by their absence 
are used. 
N/A 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
Enclosure of appliance is tested with 50N 
for 10s, no access to hazardous live 
parts. 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges (2N force) 
Wire inside the appliance are well 
secured, no risk of damage to the internal 
wiring. 
8.16 
Only special supply equipment can be used 
Supply from AC mains. 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
Approved triple insulated wire used in T1. 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device 
A mains plug that is part of direct plug-in 
equipment is used as disconnect device.  
See clause 5.4.2. 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
See above. 
N/A 
8.19.2 
Mains switch ON indication 
 
N/A 
8.20 
Switch not fitted in the mains cord 
No switches provided. 
N/A 
8.21 
Bridging components comply with clause 14 
 
N/A 
 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage. 
N/A 
9.1.1.1    a)  Determination of Hazardous Live parts 
The max. output voltage: 23,8Vdc. 
b)  Touch current measured from terminal devices 
using the network in annex D  ................................. : 
(see appended table) 
c)  Discharge not exceeding 45 µC 
0,53µC 
d)  Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous live parts. 