Read JBL ON TIME 200ID EMC - CB Certificate online
<12014165 001>
Page 10 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlet.
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
No such parts that hazardous live parts
are rendered accessible by their absence
are used.
are rendered accessible by their absence
are used.
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Enclosure of appliance is tested with 50N
for 10s, no access to hazardous live
parts.
for 10s, no access to hazardous live
parts.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges (2N force)
wiring due to hot parts or sharp edges (2N force)
Wire inside the appliance are well
secured, no risk of damage to the internal
wiring.
secured, no risk of damage to the internal
wiring.
P
8.16
Only special supply equipment can be used
Supply from AC mains.
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
Approved triple insulated wire used in T1.
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
A mains plug that is part of direct plug-in
equipment is used as disconnect device.
See clause 5.4.2.
equipment is used as disconnect device.
See clause 5.4.2.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
See above.
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
No switches provided.
N/A
8.21
Bridging components comply with clause 14
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage.
N/A
9.1.1.1 a) Determination of Hazardous Live parts
The max. output voltage: 23,8Vdc.
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
(see appended table)
P
c) Discharge not exceeding 45 µC
0,53µC
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous live parts.
P
Click on the first or last page to see other ON TIME 200ID service manuals if exist.