ON TIME 200ID (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online

 
 
<12014165 001> 
 
 
Page 8 of 73 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
IEC60065E 
 
ASTABEAB 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are used. 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used. 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No such cover which can be removed by 
hand. 
N/A 
8.5 
Class I equipment 
Class II appliance. 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
No such capacitors provided. 
N/A 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
See below. 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
Secondary circuit to primary circuit is 
separated by reinforced or double 
insulation. (The insulation system of 
switching transformer is double insulation 
system) 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
The switching transformer has been 
tested during this approval. 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
X2 capacitor (CX1) between L/N of 
primary and secondary circuits according 
to IEC 60384-14+A1 was used. 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such components. 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
Y1 capacitor (CY1) between primary and 
secondary circuits according to IEC 
60384-14+A1 was used. 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components. 
N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No such circuit. 
N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 
N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
Page of 91