Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online
<12014165 001>
Page 7 of 73
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
IEC60065E
ASTABEAB
Instructions for modem if fitted
No modern provided.
N/A
d)
Class I earth connection warning
Class II appliance.
N/A
e)
Instructions for multimedia system connection
Not multimedia system.
N/A
f)
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
A mains plug that is part of direct plug-in
equipment was used as disconnect
device.
equipment was used as disconnect
device.
P
Instructions for permanently connected equipment Not permanently connected equipment.
N/A
6
HAZARDOUS RADIATION
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation or laser inside the
EUT.
EUT.
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ..... : See above.
N/A
Emission limits under fault conditions .................... : See above.
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
P
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
any single protective device defeated except those
of Cl. 7.1 a) and b)
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table)
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION AGAINST
ELECTRIC SHOCK
ELECTRIC SHOCK
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Enamel coating of winding and the
surface material electrolytic capacitors
are not considered as safety isolation.
surface material electrolytic capacitors
are not considered as safety isolation.
P
Click on the first or last page to see other ON TIME 200ID (serv.man2) service manuals if exist.