Read JBL ON STAGEII (serv.man3) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
34 of 72
3.13.Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6 (2004)
EN 55024 specifies the IEC 61000-4-6 Standard as the basic standard for radio frequency conducted common
mode disturbance testing. This standard relates to the immunity requirements, test methods, and range of
recommended test levels for immunity to conducted disturbances induced by radio-frequency fields in the 150
kHz to 80 MHz frequency range. The standard configuration as outlined in the IEC 61000-4-6 (2004)
was used. For further information, please refer to the technical sections of the IEC 61000-4-6 (2004)
publication in addition to the test results section and photographs of the test set-up provided in this report.
For RF induced conducted common mode disturbances, EN 55024 specifies that the EUT meet at least
performance Criterion A for 3 Vrms, 1 kHz, 80% amplitude modulated waveform.
Click on the first or last page to see other ON STAGEII (serv.man3) service manuals if exist.