ON STAGEII (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 34

Read JBL ON STAGEII (serv.man3) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
Janurary 5,2006 
Harman Multimedia  OnStage UD    CE Test Report 
2006 011114 CE AUS/NZ 
 
34 of 72 
 
3.13.Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6 (2004)    
 
EN 55024 specifies the IEC 61000-4-6 Standard as the basic standard for radio frequency conducted common 
mode disturbance testing.  This standard relates to the immunity requirements, test methods, and range of 
recommended test levels for immunity to conducted disturbances induced by radio-frequency fields in the 150 
kHz to 80 MHz frequency range.  The standard configuration as outlined in the IEC 61000-4-6 (2004) 
  
was used.  For further information, please refer to the technical sections of the IEC 61000-4-6 (2004) 
  
publication in addition to the test results section and photographs of the test set-up provided in this report. 
 
For RF induced conducted common mode disturbances, EN 55024 specifies that the EUT meet at least 
performance Criterion A for 3 Vrms, 1 kHz, 80% amplitude modulated waveform. 
 
Page of 72
Display