Read JBL ON STAGEII (serv.man3) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Janurary 5,2006
Harman Multimedia OnStage UD CE Test Report
2006 011114 CE AUS/NZ
30 of 72
3.11. Electrical Fast Transient Immunity: IEC 61000-4-4 (2004)
EN 55024 specifies the IEC 61000-4-4 Standard as the basic procedure for electrical fast transient testing. IEC
61000-4-4 (2004)
defines the immunity requirements and test methods for equipment that are required to withstand high-voltage
transients coupled on supply, signal and control ports. The standard configuration for “type tests” outlined in
IEC 61000-4-4 (2004)
is
used. For further information, please refer to the technical sections in the IEC 61000-4-4 (2004)
in
addition to the test results section and photographs of the test set-up provided in this report.
For electrical fast transient/burst tests, EN 55024 requires that the EUT meet at least performance Criterion B
for ± 1 kV Power line and ± 0.5 kV signal line transients.