ON STAGEII (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL ON STAGEII (serv.man2) EMC - CB Certificate online

REPORT  # 56050AF 
 1 3   
3.   OCCUPIED BANDWIDTH – PER ANSI C63.4 ANNEX I.6 
3.1  Test Setup and Procedure 
The Test Site and EUT were set up as described in section 2.1 of this document. 
The EUT is put into the operational test mode as stated in Section 1.4 and then 
started. The spectrum analyzer had its self-calibration performed, and then set to 
the frequency to be tested, with a bandwidth of 10kHz as per ANSI C63.4 Annex 
I.6 paragraph b. The Max Peak of the Fundamental Frequency was noted, and the 
points 20 dB dB below the Fundamental Max Peak, for both sides of the signal 
was noted, and the frequency difference between these points was recorded as 
the occupied bandwidth. See below for example.  
 
Example Of Occupied Bandwidth Measurement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.2  Occupied Bandwidth Test Data.  
Frequency 
(MHz) 
Measured 
Bandwidth 
Bellow 
Fundamental 
Polarity 
Instrument 
Bandwidth 
Required 
Occupied 
Bandwidth 
Result 
Comments 
433.9  
68.4 kHz 
20dB 
Vertical 
10kHz 
1.085 MHz 
Pass 
 
433.9  
62.7 kHz 
20dB 
Horizontal 
10kHz 
1.085 MHz 
Pass 
 
 
Refer to section 3.3 for Test Data 
20dB 
Occupied 
20dB Points 
20dB Points 
Max Peak of Fundamental 
Instrumentation Bandwidth set as described in ANSI C63.4 Annex I.6 
Page of 19
Display