Read JBL ON STAGEII (serv.man2) EMC - CB Certificate online
REPORT # 56050AF
1 2
2.3 Duty Cycle Calculations
Duty Cycle = PW X (Number of Pulses) / Period
Duty Cycle = 70 ms * 10 (700 ms) / 1000 ms. = 70%
Duty Cycle = 70 ms * 10 (700 ms) / 1000 ms. = 70%
2.4 Climatic Conditions
The climatic conditions during the Radiated Emissions tests were recorded as follows:
Measured Value
Acceptable
Ambient Temperature
13 C
15 to 35° C
Relative Humidity
40%
25 to 75%
2.5 Compliant Statement
The EUT was compliant with Part 15 Subpart C
YES
NO
CA
CA Test Engineer’s Initials
PW = 70ms