Read JBL ON STAGEII (serv.man2) EMC - CB Certificate online
REPORT # 56050AF
1 1
2.2 Radiated Emissions Compliance Data
The EUT was compliant with CFR 47 Part 15 Subpart C 15.231 (a)
Fundamental Frequency Measurements and Spurious Emission Measurements
Per CFR 47 part 15 at 3 meters
Fundamental Frequency Test Data
Griffin Technology
EUT: AirClick
Amp
Cable Antenna
Total
Polarity
Freq
Meas'd Factors Factors Factors
Factors
Total
Limit
Delta
Azimuth Height
Hor
(MHz)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m) (dBuV/m) (dBuV/m)
(dB)
(degree)
(m)
Vert
434.01
67.60
26.50
4.50
18.10
-3.90
63.70
80.80
-17.10
88
1.00
Vert
QP
434.01
64.50
26.50
4.50
18.30
-3.70
60.80
80.80
-20.00
21
3.79
Hor/
QP
Meas.
Type
Ave,
QP, PK
Spurious Radiated Emissions Test Data
Griffin Technology
EUT: AirClick
Amp
Cable Antenna
Total
Polarity
Freq
Meas'd Factors Factors Factors
Factors
Total
Limit
Delta
Azimuth Height
Hor
(MHz)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m) (dBuV/m) (dBuV/m)
(dB)
(degree)
(m)
Vert
867.99
51.40
27.00
6.50
25.20
4.70
56.10
60.80
-4.70
170
1.96
Hor/
QP
867.99
48.20
27.00
6.50
24.20
3.70
51.90
60.80
-8.90
205
1.00
Vert
QP
Meas.
Type
Ave,
QP, PK
Spurious Radiated Emissions Above 1 GHz Test Data
Griffin Technology
EUT: AirClick
Duty Corrected
Amp
Cable Antenna
Total
Polarity
Freq
Meas'd Cycle
Meas'd
Factors Factors Factors
Factors
Total
Limit
Delta
Azimuth Height
Hor
(MHz)
(dBuV)
(%)
(dBuv)
(dB)
(dB)
(dB)
(dBuV/m) (dBuV/m) (dBuV/m)
(dB)
(degree)
(m)
Vert
1301.88
67.60
70%
47.32
24.22
2.68
25.39
3.85
51.17
60.80
-9.63
14
1
Vert
Peak
1735.94
60.10
70%
42.07
26.26
3.13
27.66
4.53
46.60
60.80
-14.20
192
1
Vert
Peak
1301.83
59.25
70%
41.48
24.22
2.68
25.49
3.95
45.42
60.80
-15.38
78
2.34
Hor
Peak
1735.82
52.85
70%
37.00
26.26
3.13
27.71
4.58
41.57
60.80
-19.23
76
1.52
Hor
Peak
2169.84
41.20
70%
28.84
26.51
3.61
29.74
6.85
35.69
60.80
-25.11
255
1
Vert
Peak
Meas.
Type
Ave, PK
•
Highest frequencies relative to the Limit.
Click on the first or last page to see other ON STAGEII (serv.man2) service manuals if exist.