ON STAGEII (serv.man12) - JBL Audio EMC - CB Certificate (repair manual). Page 15

Read JBL ON STAGEII (serv.man12) EMC - CB Certificate online

 
 
- Page 15 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.6.3.2 
Size of protective earthing conductors 
 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.3 
Size of protective bonding conductors 
 
 
 
Rated current (A), cross-sectional area (mm
2
), 
AWG....................................................................: 
 
— 
2.6.3.4 
Resistance (
Ω) of earthing conductors and their 
terminations, test current (A)...............................: 
 
 
2.6.3.5 Colour 
of 
insulation .............................................: 
 
 
2.6.4 Terminals 
 
 
2.6.4.1 General 
 
 
2.6.4.2 
Protective earthing and bonding terminals 
 
 
 
Rated current (A), type and nominal thread 
diameter (mm).....................................................: 
 
— 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
 
2.6.5 
Integrity of protective earthing 
 
 
2.6.5.1 Interconnection 
of 
equipment 
 
 
2.6.5.2 
Components in protective earthing conductors 
and protective bonding conductors 
 
 
2.6.5.3 
Disconnection of protective earth 
 
 
2.6.5.4 
Parts that can be removed by an operator 
 
 
2.6.5.5 
Parts removed during servicing 
 
 
2.6.5.6 Corrosion 
resistance 
 
 
2.6.5.7 
Screws for protective bonding 
 
 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
N/A 
2.7.1 Basic 
requirements 
 
— 
 
Instructions when protection relies on building 
installation 
Class III equipment. 
— 
2.7.2 
Faults not covered in 5.3 
 
— 
2.7.3 
Short-circuit backup protection 
 
— 
2.7.4 
Number and location of protective devices ........:   
— 
2.7.5 
Protection by several devices 
 
— 
Page of 77