Read JBL ON STAGEII (serv.man12) EMC - CB Certificate online
- Page 11 of 52 -
www.nemko.com
Report No. 46974
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.6 Power
interface
—
1.6.1 AC
power
distribution
systems
Class III equipment.
N/A
1.6.2
Input current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Markings and instructions
—
1.7.1
Power rating
The required marking is located
on the outside surface of the
equipment.
on the outside surface of the
equipment.
P
Rated voltage(s) or voltage range(s) (V) ...........: 18 VDC
P
Symbol for nature of supply, for d.c. only............: IEC 60417-1, symbol No. 5031,
is used.
P
Rated frequency or rated frequency range (Hz) : DC rated.
N/A
Rated current (mA or A) .....................................: 1.0 A
P
Manufacturer’s name or trademark or
identification mark ..............................................:
identification mark ..............................................:
P
Type/model or type reference .............................: on stage, on stage II
P
Symbol for Class II equipment only ...................: The equipment is Class III.
N/A
Other symbols ....................................................: The additional marking does
not give rise to
misunderstandings.
misunderstandings.
P
Certification marks .............................................: Refer to copy of markings.
—
1.7.2
Safety instructions
Provided with marking
regarding use of specified
power supply, refer to marking
label.
regarding use of specified
power supply, refer to marking
label.
P
1.7.3
Short duty cycles
The equipment is intended for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment .................................: No voltage selector.
N/A
1.7.5
Power outlets on the equipment ........................: No standard power outlet.
N/A
1.7.6
Fuse identification ..............................................: No fuses.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........:
—