ON STAGEII (serv.man12) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL ON STAGEII (serv.man12) EMC - CB Certificate online

 
 
- Page 12 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
 
1.7.8 
Controls and indicators 
No controls or figures provided.
N/A 
1.7.8.1 
Identification, location and marking ....................:   
 
1.7.8.2 Colours 
...............................................................: 
 
 
1.7.8.3 Symbols 
 
.............................................................: 
 
 
1.7.8.4 
Markings using figures   ......................................:   
 
1.7.9 
Isolation of multiple power sources ....................:  Class III equipment. 
N/A 
1.7.10 
IT power distribution systems  
Class III equipment. 
N/A 
1.7.11 
Thermostats and other regulating devices  
No thermostats or other 
regulating devices.  
N/A 
1.7.12 
Language  ...........................................................:  Instructions and markings shall 
be in a language acceptable for 
the country where the 
equipment is to be sold. 
English manual verified. 
— 
1.7.13 Durability 
The 
marking withstands 
required tests. 
1.7.14 
Removable parts 
No removable parts. 
1.7.15 
Replaceable batteries 
No battery in the equipment. 
N/A 
 Language ............................................................: 
 
— 
1.7.16 
Operator access with a tool ................................:  Class III equipment. 
N/A 
1.7.17 
Equipment for restricted access locations ..........:  Equipment not intended for 
installation in RAL.  
N/A 
 
2 PROTECTION 
FROM 
HAZARDS 
 
2.1 
Protection from electric shock and energy hazards 
 
2.1.1 
Protection in operator access areas  
Refer below: 
 
2.1.1.1 Access 
to 
energized 
parts 
Class III equipment. 
N/A 
 Test 
by 
inspection 
..............................................: 
 
 
 
Test with test finger  ............................................:   
 
 
Test with test pin  ................................................:   
 
 
Test with test probe ............................................:   
 
2.1.1.2 
Battery compartments  ........................................:  No TNV circuits in the 
equipment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No internal wiring at ELV. 
N/A 
Page of 77
Display

Click on the first or last page to see other ON STAGEII (serv.man12) service manuals if exist.