Read JBL ON STAGE (serv.man5) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 21, 2004
Harman Multimedia JBL OnStage EMC Test Report
2004 050310 EMC
26 of 80
4.10. Power Line Surge Immunity: IEC 61000-4-5 (1995),A1(2001)
This test simulates a lightning event by inducing transients onto the AC/DC power supply lines in common
and differential mode. Testing was performed in accordance with IEC 61000-4-5.
Each device was tested in a total of three surge configurations:
Surge #1: Combination Wave, Line to Protective Earth with 9uF and 10Ohm, common mode, generator
earthed.
Surge #2: Combination Wave, Neutral to Protective Earth with 9uF and 10Ohm, common mode, generator
earthed.
Surge #3: Combination Wave, Line to Neutral with 18uF, differential mode, generator floated.
For further information, please refer to the technical sections in the IEC 61000-4-5 in addition to the test results
section and photographs of the test set-up provided in this report.
Click on the first or last page to see other ON STAGE (serv.man5) service manuals if exist.