4.8.  Radio Frequency Immunity: IEC IEC 61000-4-3 (2002),A1(2002) 
 
This test bombards the EUT with electric fields that may couple into the system via chassis slots and interface 
cables and evaluates the product’s immunity.  Testing was performed in accordance with IEC 61000-4-3.  The 
RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic 
energy of a specified field strength and frequency, and monitoring the functionality of the device as the 
frequency is swept over a specified frequency range.   
 
The EUT is set up inside a shielded, semi-anechoic chamber with a radiating antenna at a distance of 3 meters 
from the EUT.  For further information, please refer to the technical sections in the IEC 61000-4-3 publication in 
addition to the test results section and photographs of the test set-up provided in this report. 