ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 26

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 26 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
5.3.3 Transformers 
There
 are no safety 
transformers in the equipment.
5.3.4 Functional 
insulation..............................................: 
Complies with c), mounted on 
V-1 or better material. 
5.3.5 Electromechanical 
components 
No electromechanical 
components in secondary 
circuits.  
5.3.6 Audio 
amplifiers in ITE  .........................................: 
Refer to appended table 5.3.
 
5.3.7 
Simulation of faults 
No thermostats, temperature 
limiters or thermal cut-outs. 
5.3.8 Unattended 
equipment 
No fire or molten metal 
occurred and no deformation 
of enclosure during the tests.
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
 
5.3.9.1 
During the tests 
No fire or molten metal 
occurred and no deformation 
of enclosure during the tests.
5.3.9.2 
After the tests 
No reduction of clearance and 
creepage distances. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
⎯ 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
⎯ 
6.1.1 
Protection from hazardous voltages 
⎯ 
6.1.2 
Separation of the telecommunication network from earth 
 
6.1.2.1 Requirements 
No TNV circuits. 
 Supply 
voltage (V)  ................................................:  
⎯ 
 
Current  in the test circuit  (mA)  ...........................:   
⎯ 
6.1.2.2 Exclusions ............................................................:   
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
 
6.2.1 Separation 
requirements 
No TNV circuits. 
6.2.2 
Electric strength test procedure 
 
6.2.2.1 Impulse 
test 
 
6.2.2.2 Steady-state 
test 
 
6.2.2.3 Compliance 
criteria 
 
 
6.3 
Protection of the telecommunication wiring system from overheating 
Page of 87