Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online
- Page 26 of 53 -
Report
No.
100711
TRF No. IECEN60950_1C
5.3.3 Transformers
There
are no safety
transformers in the equipment.
N
5.3.4 Functional
insulation..............................................:
Complies with c), mounted on
V-1 or better material.
V-1 or better material.
P
5.3.5 Electromechanical
components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N
5.3.6 Audio
amplifiers in ITE .........................................:
Refer to appended table 5.3.
P
5.3.7
Simulation of faults
No thermostats, temperature
limiters or thermal cut-outs.
limiters or thermal cut-outs.
N
5.3.8 Unattended
equipment
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P
5.3.9.2
After the tests
No reduction of clearance and
creepage distances.
creepage distances.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
⎯
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
⎯
6.1.1
Protection from hazardous voltages
⎯
6.1.2
Separation of the telecommunication network from earth
6.1.2.1 Requirements
No TNV circuits.
N
Supply
voltage (V) ................................................:
⎯
Current in the test circuit (mA) ...........................:
⎯
6.1.2.2 Exclusions ............................................................:
N
6.2
Protection of equipment users from overvoltages on telecommunication networks
⎯
6.2.1 Separation
requirements
No TNV circuits.
N
6.2.2
Electric strength test procedure
N
6.2.2.1 Impulse
test
N
6.2.2.2 Steady-state
test
N
6.2.2.3 Compliance
criteria
N
6.3
Protection of the telecommunication wiring system from overheating
N