ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 4

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 4 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Summary of testing: 
Tested according to national requirements 
for the following countries: 
All CENELEC members as listed in EN 60950-1:2006. 
All CB members as listed in CB Bulletin 112A, December  
2006. 
At the time of issuing this report only limited countries are 
listed for IEC60950-1: 2005, therefore in addition, country 
deviations for IEC60950 3rd and IEC60950-1:2001 edition 
are included. 
List from IEC 60950-1: 2001 edition: 
Australian differences: CB Bulletin No.112A, Dec 2006.  
Canadian differences: CB Bulletin No.112A, Dec 2006.  
US differences: CB Bulletin No.112A, Dec 2006. 
Singapore differences: CB Bulletin No.112A, Dec 2006.  
Korean differences: CB Bulletin No.112A, Dec 2006. 
Israeli differences: (not related to CB Bulletin No.112A, 
December 2006). 
Japanese differences: CB Bulletin No.112A, Dec 2006. 
Chinese differences: CB Bulletin No.112A, Dec 2006. 
 
General: 
Normal load as described in Annex L or as 
close as possible to the most severe 
normal use. 
Normal operation is considered 1/8th of maximum 
undistorted power.  Non-clipping was determined using a 1 
KHz sinusoidal signal input. For maximum normal operation, 
1/8th of the non-clipping amplitude was used with a filtered 
pink noise input signal. 
 
1.5, 2.5. 3.2 External Power Supply 
The external power supply was not evaluated as part of this 
report. An external power supply approved to IEC 60950 shall 
be provided. The external power supply The external power 
supply output shall be separately certified as limited power 
source, complying with the national regulations of the 
countries in which the appliance is to be sold. 
 
1.7.2 Safety instructions, required markings 
regarding use of a specified power supply 
Class III Equipment with an enclosure made of V-2 material, 
using a non-special connector for the DC input must have a 
marking stating the manufacturer and model number of the 
power supply to be used. Marking is provided. 
 
1.7.12 Language of safety 
markings/instruction 
Instructions and equipment marking related to safety 
shall be applied in a language, which is acceptable in the 
country in which the equipment is to be sold. 
 
 
Page of 87
Display