Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 62 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.3
TABLE: Fault condition tests
P
Ambient temperature (
°C) ...................................: Refer to below
⎯
Power source for EUT: Manufacturer, model/type,
output rating .........................................................:
output rating .........................................................:
Refer to first page
⎯
Component
No.
Fault
Supply
voltage
(V)
Test time
Fuse #
Fuse
current
(A)
Observation
Ventilation
openings
openings
Blocke
d
264 1.5h F1
(inside
adaptor)
0.12
Unit operated normally, no
hazards, no damaged. Max.
measured temp. in L2= 88.8°C,
PCB= 86°C, Enclosure=62.8°C,
ambient= 25.9°C
hazards, no damaged. Max.
measured temp. in L2= 88.8°C,
PCB= 86°C, Enclosure=62.8°C,
ambient= 25.9°C
+5V output
s-c
264
5 min
F1
(inside
adaptor)
0.13
Normal operation. No hazard.
+3.3V output
s-c
264
5 min
F1
(inside
adaptor)
0.11
Speaker output shut down. No
hazard.
hazard.
Speaker s-c
264
5min
F1
(inside
adaptor)
0.05
Unit shut down. No hazard.
supplementary information:
S-c = short circuit