ON STAGE 200ID - JBL Audio EMC - CB Certificate (repair manual). Page 60

Read JBL ON STAGE 200ID EMC - CB Certificate online

 
 
- Page 59 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
4.5 
TABLE: Thermal requirements 
 
Supply voltage (V)  .....................
90V / 50Hz 
264V / 60Hz 
⎯ 
Maximum measured temperature T of 
part/at:: 
T (
°C) 
Allowed 
T
max
 (
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped 
output power, & charging Ipod (500mA 5V) 
Adaptor enclosure 
45.1 
48.5 
80.3 
Plug part of adaptor enclosure 
32.5 
32.7 
80.3 
PCB under IC U5 
79.4 
86.2 
90.3 
L2 81.4 
88.7 
115.3 
PCB near Q5 
70.5 
74.6 
90.3 
C13 69.6 
74.9 
90.3 
External enclosure of speaker 
57.6 
62.1 
80.3 
External enclosure near Ipod socket 
40 
40.8 
80.3 
External enclosure near on/off switch 
41.3 
43.5 
80.3 
Ambient 25.5 
25.3 
-- 
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated 
based upon a (minimum) test temperature of 25.3°C. Temp. limits are adjusted according to Cl. 1.4.12.3. 
Temperature limits include less 10K for thermocouple measurement method. 
Temperature T of winding: 
t
1
 (°C)
R
1
 (
Ω)
t
2
 (°C)
R
2
 (
Ω)
T (
°C) 
Allowed 
T
max
 (
°C)
Insulatio
n class
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
supplementary information: 
 
 
Page of 103