Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 59 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.5
TABLE: Thermal requirements
P
Supply voltage (V) .....................
90V / 50Hz
264V / 60Hz
⎯
Maximum measured temperature T of
part/at::
part/at::
T (
°C)
Allowed
T
max
(
°C)
Supplied 1KHz sine wave for speakers in computer speaker system and obtain 1/8 Maximum non-clipped
output power, & charging Ipod (500mA 5V)
output power, & charging Ipod (500mA 5V)
Adaptor enclosure
45.1
48.5
80.3
Plug part of adaptor enclosure
32.5
32.7
80.3
PCB under IC U5
79.4
86.2
90.3
L2 81.4
88.7
115.3
PCB near Q5
70.5
74.6
90.3
C13 69.6
74.9
90.3
External enclosure of speaker
57.6
62.1
80.3
External enclosure near Ipod socket
40
40.8
80.3
External enclosure near on/off switch
41.3
43.5
80.3
Ambient 25.5
25.3
--
Having a specified maximum ambient temperature of 40°C, the maximum temperatures are calculated
based upon a (minimum) test temperature of 25.3°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
based upon a (minimum) test temperature of 25.3°C. Temp. limits are adjusted according to Cl. 1.4.12.3.
Temperature limits include less 10K for thermocouple measurement method.
Temperature T of winding:
t
1
(°C)
R
1
(
Ω)
t
2
(°C)
R
2
(
Ω)
T (
°C)
Allowed
T
max
(
°C)
Insulatio
n class
supplementary information: