IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.2.8
Cathode ray tubes
CRT(s) not used in the
equipment.
equipment.
N
Picture tube separately certified ............................ :
⎯
4.2.9
High pressure lamps
No high pressure lamps in the
equipment.
equipment.
N
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
Not intended to be mounted
on a wall or ceiling.
on a wall or ceiling.
N
Measuring instrument
Inv. no.
Date
4.3
Design and construction
⎯
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) .............:
No knobs, grips, handles,
lever etc that might create
hazard.
lever etc that might create
hazard.
N
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N
4.3.4
Securing of parts
No loosening of parts
impairing creepage distances
or clearances is likely to
occur.
impairing creepage distances
or clearances is likely to
occur.
P
4.3.5
Connection by plugs and sockets
SELV connectors do not
comply with IEC 60320 or IEC
60083.
comply with IEC 60320 or IEC
60083.
P
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
into a wall socket-outlet.
N
Torque
.................................................................. :
⎯
Compliance with the relevant mains plug standard
.............................................................................. :
N
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
provided.
N
4.3.8
Batteries
No batteries in the equipment.
N
- Overcharging of a rechargeable battery
N